Admin » Prisma SSR EyeLink

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
tools:eyetracking:prismaeyelink [2024/10/14 17:29] – willtools:eyetracking:prismaeyelink [2025/08/27 13:12] (current) – hardware log will
Line 1: Line 1:
-====== Prisma EyeLink ======+====== Prisma SSR EyeLink ======
  
   * The EyeLink Tray Mounted Camera needs to be placed before the study.    * The EyeLink Tray Mounted Camera needs to be placed before the study. 
Line 6: Line 6:
  
 Both of these are stored in the Prisma one scan room closet. Both of these are stored in the Prisma one scan room closet.
 +
 +== Hardware log ==
 +
 +  * 2025-08-26 - P2 mirror fell out! scuffed
  
 == EyeLink SetUp - Prisma 2 ==   == EyeLink SetUp - Prisma 2 ==  
Line 12: Line 16:
   - Ensure EyeLink Host PC is turned on   - Ensure EyeLink Host PC is turned on
   - Ensure monitor and keyboard are switched to show the EyeLink computer (option #2)   - Ensure monitor and keyboard are switched to show the EyeLink computer (option #2)
-  - Open the ''Manually_Set_IP.txt'' file on the desktop (for  IP address reference later)+  - Open the ''Manually_Set_IP.txt'' file on the task pc desktop (for  IP address reference later)
   - Adjust Windows IP address settings   - Adjust Windows IP address settings
      - Click on the **control panel**      - Click on the **control panel**
Line 41: Line 45:
   - confirm camera is in focus and thresholds are reasonable   - confirm camera is in focus and thresholds are reasonable
     - if pupil thresholding cannot be established with value above 65, the IR is likely not hitting the eye.     - if pupil thresholding cannot be established with value above 65, the IR is likely not hitting the eye.
 +
 +== Clean up ==
 +  - **RESET THE IP ADDRESS BACK TO UPMC**
 +    - follow the same control panel -> network properties -> adapter settings  as above but use <code>10.48.88.???</code>
 +  - remove the ethernet coord from the task computer (back to disconnected like before) 
 +  - Gentle reminder to switch back eyetracking monitor and keyboard are switched back to show original screen (option #1)
 +  - save the (hopefully) amazing ET data then LogOff of Luna on EPrime
 +